TFML (Transfer Function
Module Library)
Functional
Downloads
Below are applications written in FORTH programming language, for Medacs units.
TFML Instruction Guide included in all downloads.
All files will download in less than 10 seconds on a standard modem.
Summary |
General Operation |
Suitable For |
Ref. Number |
Sensor Validation |
Produces a 4-20 mA output proportional to average of two sensor inputs as long as both sensors are in bounds. If either sensor goes out of bounds it is rejected and the output then becomes proportional to the ‘good’ sensor. A relay contact is set to annunciate the sensor failure which can be changed at the next scheduled maintenance. |
MED2213 |
02011111
|
General pulse totalizer |
PV is taken as a flow rate. Output 2, relay A is pulsed for a user-configurable time when the integrated total reaches a user-configurable value. |
MED2113, MED2122, MED2133 |
02011011
|
Rate of change limiter |
Operates as a standard transmitters but limits the maximum rate of change of the output to a user defined value. |
MED2113 |
02010921
|
Peak/Valley Pick & Hold |
Provides a display an analog O/P proportional to either the peak or valley input which is reset by an external digital. The peak/valley also decays as a rate defined in TFML3. |
MED2213 |
02010911
|
Pulse Totalizer |
Takes 0-10V DC input equivalent to 0-400m3 hr and provide 2 outputs. Output 1 4-20mA = 0-400m3 hr, output 2 relay 1 high alarm, relay 2 pulse per total. For pulse output, relay ‘on’ time = 100ms. |
MED2113 |
02010211
|
PI control – Relay Output |
This is the conventional PI control whereby a control
signal is derived which is proportional to the error and the integral of the
error. The output is sent to the proportioning relay output
|
MED2133 |
02010711
|
PID - 3 term control - continuous |
This is the conventional PID control whereby a control
signal is derived which is proportional to the error, the integral of the
error and the derivative of the error. The setpoint and PID constants are
entered via TFNL registers.
|
MED2113 |
02010311
|
A-B |
Provides an analog output proportional to the difference between the two inputs. |
MED2211 |
01120411
|
A+B
|
Provides an output equal to the sum or average of both
inputs (or some other sub-multiple of the sum).
|
MED2211, MED2213 |
01120421
|
Sample and Hold |
4-20mA output related to input, the digital input initiates the hold, and the digital output is used as an alarm. |
MED2113 |
01120611
|
High Input Selector |
This module takes two inputs and produces a 4-20 mA
output proportional to the highest of the two inputs.
|
MED2213, MED2211 |
01120512
|
| NOTE: When using single channel unit the TFML prompt will appear as tFnL on the unit display. | |||